Mosquito Magnet Patriot Owner's Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 35
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
10
Maintenance
9
Instructions
Starting Instructions
It is recommended that you read the entire manual
before starting the Mosquito Magnet
®
trap.
1. Insert Octenol or Lurex3 cartridge in compartment per
instructions in cartridge packaging.
2. Connect regulator to propane tank (see page 8).
3. Plug power connector into the trap.
4. Plug AC adapter into electrical socket. (To avoid the risk
of electrical shock, connect only to properly grounded
outlets.) Adapter unit is not intended to be mounted.
5. Slowly turn propane tank valve on.
6. Turn rocker switch to “on” position.
7. The red light on the switch will flash for up to 20 minutes
(warm up phase).
8. Once the light stops flashing and is solid, the Mosquito
Magnet is fully operational.
NOTE: Should you experience an interruption of power,
be sure to restart trap.
Shut Down Instructions
To shut down the Mosquito Magnet, simply close the valve
on the propane tank and switch to the “off” position.
When Not In Use
If the unit is not in use, the gas must be turned off at the
supply cylinder. Storage of this unit indoors is permissible only
if the cylinder is disconnected and removed. Cylinders must
be stored outdoors, out of reach of children and must not be
stored in a building, garage or any other enclosed area.
End of Season Storage
Push ON/OFF switch to OFF position to shut down the
trap. The LED light will go out and the fan will continue
running until trap is cool. Close the propane tank valve
and disconnect regulator.
Any open Mosquito Magnet
®
Octenol or Lurex3
cartridges should be removed and discarded. See
cartridge label for disposal instructions. The bug bag
should also be discarded prior to storing the trap.
STORAGE: The trap should be stored indoors in a garage
or shed in the off-season. Cover trumpet to prohibit insects
from nesting. Cover unit with trap cover available at
www
.mosquitomagnet.com or with a tarp and secure tightly
at the bottom to keep out dust, spider webs and other debris.
NOTE: It is recommended that you use the Quick Clear
adapter before seasonal storage to avoid build-up
of contaminants during off-season (see page 11).
Maintenance
21 Day Maintenance Cycle
- Refill propane. 20 lb (9.07 kg) propane tank lasts approximately
21 days with 24-hour/7-days operation.
- Replace Octenol or Lurex3 cartridge.
See cartridge label for instructions.
- Empty or replace bug bag.
- Utilize the Quick Clear adapter at every tank change.
Periodically wipe down the outside of the trap
with a clean, water damp cloth.
Propane Tank Changing Tips
When attaching the regulator knob to a tank after a tank change,
be sure to fully tighten the regulator knob onto the tank. No need
to use tools, but do turn the knob as far as possible by hand.
When this is done, loosen the knob 1/4 turn, then re-tighten to
maximize seal.
The purpose for this is to fully engage the regulator onto the tank. If
the regulator is not fully engaged, the flow of gas may be restricted
to the point where the trap will show a gas empty code. If this
occurs, press the off button, close the tank valve, and remove the
regulator from the tank. Re-attach the regulator and try again.
**READ MANUAL BEFORE STARTING**
Possible CauseMaintenance Schedule
Note: Bug bags should be replaced when half full.
You can find all your accessory needs at your local hardware or home improvement store.
Example
Season 1 Season 2 Season 3 Season 4
Purchase Date
Register Warranty
Start Up Date
SERVICE:
Seasonal Tune-Up
MAINTENANCE:
Propane & Octenol/Lurex3 Cartridge Change
Quick Clear Cartridge Change
Propane & Octenol/Lurex3 Cartridge Change
Quick Clear Cartridge Change
Propane & Octenol/Lurex3 Cartridge Change
Quick Clear Cartridge Change
Propane & Octenol/Lurex3 Cartridge Change
Quick Clear Cartridge Change
Propane & Octenol/Lurex3 Cartridge Change
Quick Clear Cartridge Change
SERVICE - WINTERIZATION
Discard Bug Bag & Octenol/Lurex3
Cartridge
Cover Trap Trumpet to avoid
nesting insects
Keep in garage or shed
4/1
4/1
4/1
4/21
4/21
5/11
5/11
5/31
5/31
6/20
6/20
7/10
7/10
For Best Results (unit must run for 24 hours/day)
Your trap will begin capturing immediately with
significant reduction in the mosquito population in
7-10 days. Allow 4 weeks to significantly reduce the
mosquito population in your yard.
Allow trap to cool for 5 minutes before re-start.
Never spray insecticide in or around trap.
Trap can be left running in the rain.
If using lime or fertilizer compounds, be sure to shut
down the trap first to prevent dust or fine mist from
being drawn into trap and clogging bug bag.
Warning: Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage. Read
the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
Caution: The gas pressure regulator provided with this
appliance must be used. This regulator is set for an outlet
pressure 11.0 in. water column.
The gas supply must be turned off at the LP-Gas supply
cylinder when this appliance is not in use.
3/15
Page view 5
1 2 3 4 5 6 7 8 9 10 11 ... 34 35

Comments to this Manuals

No comments